Siemens TC12 Installation, Commissioning And Maintenance Handbook page 24

Installation, commissioning and maintenance handbook
Table of Contents

Advertisement

2.2.2.4.2 Rack Mount Wall Map PC
A rack mount PC which is to be used for driving the LEDs on a wall map would
normally have the following, additional, cards installed in it.
• Ethernet Card (Etherlink 3) (not needed if processor card has built-in
Ethernet)
• Digi I/O Card (1 per digital output rack)
2.2.2.4.3 Flat Panel Data Transmission PC
A flat panel PC which is to be used for data transmission would normally have
the following, additional, cards installed in it.
• Digi I/O Card
• Intelligent Modem Driver Card (IMD) Xem.
2.2.2.5 3Com Etherlink 3 Ethernet Card Set Up
The Ethernet card (part number 667/7/22609/014) needs a half slot in the PC; a
full slot can be used if there are no half slots available.
The setting up of a 3Com Etherlink 3 card is described below. There are no links
or jumpers on the card and the set up is performed using a configuration program.
With the Ethernet card installed in the PC, the PC booted up and at the C: DOS
prompt The TC12 software installation disk should be inserted into the PC's floppy
drive and the following command used to run the set up program:
A:\ELNK3\3C5X9CFG.EXE
The set up part of the program to set the parameters listed below to the values
shown:
Plug and Play
I/O Base Address
Interrupt Request Level
Transceiver type
Network Driver Optimisation DOS Client
Note: If Plug and Play is enabled, this should be disabled first, the configuration
saved and the PC rebooted before any other settings are changed.
2.2.2.6 UM9008 On-Board Ethernet Set Up
Where the processor card has a built-in Ethernet controller (UM9008) the UM9008
configuration and diagnostic utility program should be run before any boards are
installed in the PC. To run the program the TC12 software installation disk should
be inserted into the PC's floppy drive and the following command used to run the
diagnostic utility program:
A:\UM9008\DIAG9008.EXE
The first screen of the DIAG9008 program shows the current configuration with the
options of Accept and Exit, Diagnostics, or Configuration. To change the
configuration, select Configuration, followed by Modify Configuration. The arrow
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
Disabled
300H
3
Auto Select
Page 14
Issue 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents