3.3.3.63 Display Mains State Inputs (KDI)
KDI (input port number: 0 - 3) <enter>
Comment:
The state of the input is only sampled at mains peaks so that the value displayed
indicates whether the particular mains supply is on or off (because the voltage
sensor output fluctuates depending on the point in the mains cycle, if the input was
sampled at other times e.g. the zero cross over point, the display may indicate that
the particular mains supply was off, erroneously).
3.3.3.64 Display Lamps ON/OFF State (KLM)
KLM (lamp supply: 0 - 1) <enter>
Comment:
3.3.3.65 Display LMU Learn Status (KLS)
KLS <enter>
Comment:
3.3.3.66 Display Comms Message Log (GCT)
GCT (comms log code: 0 - 6)
Comment:
Note: To clear the comms log enter the command GCT 0 = 65535
Comms Log Code
0
1
2
3
4
5
6
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
Indicates the dim/bright state for each of the controller lamp
supplies as shown below:
0 - state undefined (no change has occurred)
1 - dim
2 - bright
Enables the state of the LMU mains state inputs to be displayed in
binary format.
Indicates the state for each of the controller lamp supplies as
shown below:
6 - lamps off
7 - lamps on
8 - change in progress (debounce period)
Displays the combined learn status bits for all aspects of all
configured sensors. Refer to KAS command, bits 0 to 3, for the
status bit definitions and layout. Only bits 0 to 3 are displayed, bits
4 to 7 are always 0.
Enables comms message and error counts to be displayed.
good messages
CRC errors
framing errors
sync errors
sync timing errors
sync byte corrupt errors
4 second time out errors