Free Standing OTU interface task errors - Function Group 7:
free standing interface task case out of range
free standing interface task port verify error
LMU task errors - Function Group 8:
LMU task case out of range
LMU RLM data fault
RAM fault
Interrupt Function errors - Function Group 9:
local port verify error
ADC failure error
DFM Task error - Function Group A
DFM task case out of range
Fault data index 227 Hard Error Code (Fault flag 13)
Contains hard error code number:
0 - Unspecified error
1 - RAM enable error
2 - RAM Pattern test error
3 - RAM read/write error
4 - PROM error
5 - Too many Soft Errors
Fault data index 228 - 239 DFM failure data (Fault flag 15)
228 - port 0 DFM data ( Bit 0 = input 0)
239 - port 11 DFM data
Each bit that is set indicates a failed detector input
Note: Only ports 0 to 3 apply to Freestanding OTU.
3.3.3.29 Display Lamp Faults with Phase information (KLP)
KLP displays the lamp fault data in KLD0 to KLD215 in a more user friendly
format. This command is supported by PB392 firmware Issue 3 onward.
The response is in the format
Where - 'P' is the phase letter
'cccccc' is the phase colour
'+I' is the number of current increases (if any)
'-F' is the number of lamp failures (or 0 if none).
Example
Press the '+' key <Enter> "B/RedMan -1" 1st non-zero fault
Press the '+' key <Enter> "B/GrnMan +1 -0" 2nd non-zero fault
Press the '+' key <Enter> "P/Wait
Press the '+' key <Enter> "KLP End of log
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
"P/cccccc +I
Type 'KLP' <Enter> "A/Red
Page 102
1
2
1
2
3
1
2
1
-F"
0" is displayed
+1 -0" 2nd non-zero fault
(no more faults)
Issue 10