Siemens TC12 Installation, Commissioning And Maintenance Handbook page 120

Installation, commissioning and maintenance handbook
Table of Contents

Advertisement

'Q?'
'H?'
'S?'
'L?'
3.3.3.53 Display Firmware Identity and Issue state (GIC, KIC)
GIC<enter>
Comment:
3.3.3.54 Display PLD Variant (GPV, KPV)
GPV<enter>
Comment:
3.3.3.55 Display Reply Data (GRD)
GRD (reply byte number: 0 - 14) <enter>
Comment:
Note: GRD 0 displays the first byte of the reply message that is the OTU
address, MT bit etc. The first byte of reply data is accessed using GRD 1.
The display is only valid for the configured number of reply bytes.
3.3.3.56 Display Lamp Monitor ADC readings (KAC)
KAC (sensor number: 1-23) (current/voltage selector: 0-1) <enter>
Comment:
Note: The lamp monitor facility must be enabled for ADC readings to be
available.
3.3.3.57 Display learnt load (KEL)
KEL (sensor number: 1 - 23)(aspect pattern number, 0-6):<enter>[PB392 issue 6
Comment:
3.3.3.58 Display actual current (KES)
KES (sensor number: 1-23)<enter>
Comment:
3.3.3.59 Display lamp supply voltage (KEV)
KEV (Lamp Supply: 0-1)<enter>
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
to identify up to four loops.}
Input is assigned to Queue Unit ?
Input is assigned to HIOCC Unit ?
Input is assigned to Scoot Unit ?
Input is assigned as a Mains state for sensor ?
Displays Firmware Reference Number and Issue State.
Displays PLD Reference Number and Issue State.
Enables the reply data currently being transmitted to the instation to
be displayed in binary format.
Displays the ADC current or voltage readings for configured Lamp
Monitor sensors.
Displays the learnt loan in Watts at 240 V, with the associated
phase and colour. If the load is not learnt, the display will indicate
zero.
Displays the last current reading in milliamps on the Red or the
associated phase and colour.
Page 110
or later]
Issue 10