3.3.3.41 Disable/enable Lamp Monitor (KLE)
KLE = 0 or 1
Comment:
3.3.3.42 Lamp Monitor reset (KLR)
KLR = 1
Comment:
3.3.3.43 OTU output bit source (KOL, GOL)
GOL {Output bit number: 0 - 15} = { Output function: 0 - 255 } (0)
Comment:
3.3.3.44 Red lamp monitor - 2nd failure disable (KRD)
KRD = 1
Comment:
3.3.3.45 Red lamp monitor - disable/enable (KRE) L
KRE {sensor number 1 - 23 } = { 0 or 1 } (0), [ (1) for pre PB392 issue 2.]
Comment:
3.3.3.46 Red Lamp Monitor Group allocation (KRG) L
KRG {sensor number 1 - 23 } = { 00000000 - 11111111 } (0)
Comment:
3.3.3.47 Second Lamp Supply (KSS)
KSS = {sensor number 0 - 22 } (0)
Comment:
666/HE/43100/000
TC12 Installation, Commissioning & Maintenance Handbook
To enable or disable the Lamp Monitor facility (1 = enabled)
Causes LMU to reset and relearn the lamp characteristics. This
command must always be used before enabling the LMU for the
first time.
Defines the function of the OTU hardware outputs. The output
function is as described for the GRL command (see section
3.3.3.13 except those marked *). The normal default is direct from
the UTC control bytes.
Used to temporarily remove the 2nd Red lamp failure output. This is
required to restart part time controllers that shut down when two red
failures occur.
To select normal lamp monitoring (i.e. not red lamp monitoring) on
vehicle phases set this value to 0 for each intersection vehicle
sensor.
Enables lamp faults associated with a particular sensor number to
be allocated to one or more of eight monitor groups whose outputs
provide the lamp fault signals to UTC and the controller. Setting bit
0 maps the sensor to group 0 etc.
For dual controller applications defines the input number to be used
for the second controller lamp supply voltage transformer.
Page 108