3. On the Dialing Pattern tab of the Out Call Routing Configuration window, add
dialing pattern definition entries for the following prefixes:
prefix = 0, length = 11
prefix = 00, length = 14
prefixes = 1-9, each length = 7
In the Route Priority field, use the drop-down list to select the En-Bloc route
definition (assigned in step 2).
The Dialing Pattern tab should look as follows:
With this configuration, the system will see that all digits have been collected and will
send digits to the CO, instead of waiting 7 seconds for the dialing to finish.
Resolving Dialing Delay for Non-USA/Canada Countries
MAXCS ACM 6.5 Administration Manual 193