Table 15 Copy pair statuses of volumes obtained by the YKQRYDEV command (Cnt Ac-J Z)
(continued)
Copy pair status acquired by
YKQRYDEV
SUSPER (09)
SUSPER (50)
TRANS (60)
TRANS (61)
SUSPER (62)
HOLD (70)
HOLDER (71)
HOLDTRNS (72)
HOLDER (73)
NODELTA (74)
Table 16 Copy pair statuses of volumes obtained by the YKQRYDEV command (BC Z)
Copy pair status acquired by
YKQRYDEV
SIMPLEX
PENDING (01)
DUPLEX (02)
TRANS (03)
SUSPOP (04)
PENDING (05)
SUSPER (06)
SUSPVS (07)
68
Business Continuity Manager with replication products
Status of the copy pair in the
storage system
Suspended
Suspended
Suspending
Deleting
Suspended
HOLD
HOLDER
HOLDTRNS
HOLDER
NODELTA
Status of the copy pair in the
storage system
Simplex
Pending
Duplex
Sp-Pend
Split
Resync
Suspend
V-Split
Description
The copy pair has been suspended because the primary
storage system detected that the pair control information
stored in memory was lost when the power was turned on
(IMPL). This error occurs when the primary storage system
is turned off after the backup time for non-volatile memory
has been exceeded.
The copy pair has been suspended because the data
between the P-VOL data and the S-VOL data did not match
during the initial copying phase. Invalid track formatting
causes this error.
The copy pair is changing to the suspend status.
The copy pair is changing to the Simplex status.
The primary storage system has suspended all the copy
pairs due to a planned outage (turned off).
Copy pairs are ready to perform a Delta Resync, and a
delta resync can be performed.
A transition was performed to the HOLDER status indicating
that the differential data cannot be kept in a journal, due
to a hardware failure such as a cache memory, shared
memory, or journal volume failure.
The status of a Delta Resync pair is being changed to the
HOLD status.
The user tried to perform a Delta Resync, but the copy pair
changed to the HOLDER status because the copy pair is
not in a status that allows for Delta Resync. In this situation,
the differential data cannot be retained as journal data.
Status when the user performs a Delta Resync, but the
differential data between the journal on the P-VOL of the
copy pair receiving the command and the journal on the
S-VOL of the copy pair receiving the command cannot be
properly applied to the S-VOL. Delta resyncs cannot be
performed in this status, but a full copy Delta Resync can
be performed.
Description
SIMPLEX status
Pending status (during initial copy).
Duplex status.
Transitioning to the suspend status in normal mode.
Suspend status.
Resynchronization is being performed.
SUSPER status.
Transitioning to the suspend status in quick mode.