6.
From the primary site, execute the YKRESYNC FORWARD command for the Continuous Access
Synchronous Z copy group container.
The Continuous Access Journal Z copy pair automatically changes to the SUSPEND status as
the result of resynchronization of the Continuous Access Synchronous Z copy pairs.
YKQUERY
YKRESYNC FORWARD
YKEWAIT GOTO(DUPLEX)
7.
Execute the YKEWAIT GOTO(SUSPEND) command, and wait until the status of the Continuous
Access Journal Z copy pair has changed to SUSPOP.