Operands; Example; Return Codes For Business Continuity Manager Monitor; Operator Commands Available In Bcm Monitor - HP XP P9500 Software User's Manual

Hp p9000 business continuity manager user guide
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

CANCEL
1cataloged-procedure-for-startup-name

Operands

cataloged-procedure-for-startup-name
Used to specify the name of the cataloged procedure for startup that was specified in the START
command when Business Continuity Manager Monitor was started.
identification-name
Used to specify the identification name that was specified in the START command when Business
Continuity Manager Monitor was started.

Example

To forcibly stop the Business Continuity Manager Monitor instance whose identification name is
YK, enter the following command:
CANCEL YK

Return codes for Business Continuity Manager Monitor

"Return codes issued when Business Continuity Manager Monitor is stopped" (page 520)
return codes issued when Business Continuity Manager Monitor stops.
Table 89 Return codes issued when Business Continuity Manager Monitor is stopped
Return Code (Decimal Format)
0
4
8
12
Other

Operator commands available in BCM Monitor

Business Continuity Manager Monitor supports the operator commands shown in
of Business Continuity Manager Monitor commands" (page
commands, you can change the behavior or check the status of Business Continuity Manager
Monitor while it is running. Operator commands are executed after all the actions Business Continuity
Manager Monitor is currently performing are finished.
520 Automatic operation using BCM Monitor
Meaning
BCM Monitor terminated normally.
The child task terminated abnormally.
One of the following errors occurred while analyzing the
Business Continuity Manager Monitor parameter files:
An attempt to access the Business Continuity Manager
Monitor parameter files failed.
The settings specified for the Business Continuity
Manager Monitor parameter files are invalid.
GETMAIN failed.
One of the following errors occurred when not analyzing
the Business Continuity Manager Monitor parameter files:
An error occurred when specifying the initial settings.
No profile has been defined in the RACF FACILITY class.
Business Continuity Manager Monitor has not started
via IKJEFT01.
GETMAIN failed.
BCM Monitor was stopped by a startup action, an action,
or an error action with EXIT specified. The return code
specified for EXIT will be issued.
521). By executing these operator
shows the
"List of functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents