Table 160 Values That Can Be Specified as Actions (continued)
Specifiable value
SENDMSG(output-message,{CONS|ERROR|STATUS|INFO})
STOPPOINT(label-name)
PAUSE(sleep-time)
Below are details about the values that can be specified as actions.
NOP
Does nothing.
EXIT(return-code) ~ <numeric characters> ((0 to 4095))
Stops BCM Monitor with the specified return code. HP recommends hat you specify a value other
than 0, 4, 8, or 12 because these numbers are already used as BCM Monitor return codes.
REPORT(copy-group-ID[,{SUMMARY|DETAIL|STATS|RPO}[,{CONS|ERROR|STATUS|INFO}]])
Outputs report information for the specified copy group.
{SUMMARY|DETAIL|STATS|RPO}
Specifies the type of report information:
SUMMARY
Outputs summary information about the copy group.
DETAIL
Outputs detailed information about the copy group.
STATS
Outputs operating information for the copy group. This can only be used for the TCA and CAJ
copy types.
RPO
Outputs consistency information for the copy group. This can only be used for the TCA and CAJ
copy types.
{CONS|ERROR|STATUS|INFO}
Specifies the message level of the messages that are to be output as report information. For details
on which messages are output for which message level settings, see
for the Message Level and the Messages that Are Output for Each Level" (page
WAITFOR(copy-group-ID,{DUPLEX|SUSPEND|SIMPLEX|SUSPVS|HOLD}[,timeout-value])
Executes the YKEWAIT command for the specified copy group and waits until the status changes
to the copy group status specified in this parameter. Note that if the specified timeout value is
reached before the specified status is obtained or if an invalid status results, the error action is
executed. For details on invalid statuses, see
GOTO Parameter" (page
{DUPLEX|SUSPEND|SIMPLEX|SUSPVS|HOLD}
Specifies the status of the copy group that is specified in the GOTO parameter of the YKEWAIT
command. After all copy pairs in the copy group have changed to the specified status, the
processing terminates normally. For details on this value, see the description of the GOTO parameter
in
"YKEWAIT Command" (page
timeout-value ~ <numeric characters> ((0 to 9999))
"Invalid Status for Each Value Specifiable in the
207).
205).
Overview
Outputs the specified character string as a
message.
Specifies the point at which BCM Monitor is to
be stopped or sleeped.
Sleeps BCM Monitor.
"Values that Can Be Specified
YKMONCG File 367
358).