Table 103 YKENV Command Return Code List
Return code
0
—2
—1
Output items
The table below lists and describes the items that are output during execution of the YKENV
command in the order they are output.
Table 104 Items Output by the YKENV Command
Output item
HP P9000 for Business Continuity Manager Software
Business Continuity Manager environment variables
(v.r.m-nn(zz))
Host ID:
License info DSN prefix:
Business Continuity Manager log output method:
CLI log output settings:
YKCMDIF =
&YKCMDIF =
YKLCNSE =
&YKLCNSE =
YKLCNS2 =
&YKLCNS2 =
LOGPUT =
Meaning
The command terminated normally.
A module could not be loaded. Possible causes are as
follows:
The library dataset has not been linked.
The module is protected by the RACF program control
function.
An interruption occurred during execution.
Description
Name of the program product
Business Continuity Manager environment variables are
output below this line. v.r.m-nn(zz) indicates the version
number and build number.
Host ID
Prefix of the license information dataset.
Business Continuity Manager log output method.
LOGR: The system logger service is used to output the
Business Continuity Manager log.
SAM: The Business Continuity Manager log is output to
a SAM file
CLI command-execution log output settings.
YES: The CLI command-execution log is output.
NO: The CLI command-execution log is not output.
Value of the Business Continuity Manager environment
variable YKCMDIF, which was set by the YKSETENV
command. If YKCMDIF is not set, N/A is displayed.
Value of the system symbol &YKCMDIF. If &YKCMDIF is
not set, N/A is displayed.
Value of the Business Continuity Manager environment
variable YKLCNSE, which was set by the YKSETENV
command. If YKLCNSE is not set, N/A is displayed.
Value of the system symbol &YKLCNSE. If &YKLCNSE is
not set, N/A is displayed.
Value of the Business Continuity Manager environment
variable YKLCNS2, which was set by the YKSETENV
command. If YKLCNS2 is not set, N/A is displayed.
Value of the system symbol &YKLCNS2. If YKLCNS2 is not
set, N/A is displayed.
Value of the Business Continuity Manager environment
variable LOGPUT, which was set by the YKSETENV
command. If LOGPUT is not set, N/A is displayed.
Command details 203