Table 77 Contents of the Volume Query Information (CAJ) Panel (continued)
Item
1
Displayed if P-VOL or S-VOL is shared with other copy pairs in the definition (for example, in a
1:n BC copy pair configuration or when S-VOL for CAA is used as P-VOL for BC).
2
MISMATCH might be displayed. This happens when the device information at definition, as
indicated by Primary Volume and Secondary Volume, differs from the device information reported
by the storage system. In this case, the device information reported by the storage system is
displayed in the Pair Volume column. If MISMATCH is displayed, check the configuration file used,
as well as the actual storage system configuration information settings.
150 ISPF Panels
Dir
Pair Volume
SN
DEVN
Status
SN
SSID
CU
CCA
DEVN
Description
For Primary: storage
system serial number of
the P-VOL of the copy
pair specified in the
Copy Group Pair Status
panel
For Secondary: storage
system serial number of
the S-VOL of the copy
pair specified in the
Copy Group Pair Status
panel
For Primary: Device
number of the P-VOL of
the copy pair specified in
the Copy Group Pair
Status panel
For Secondary: Device
number of the S-VOL of
the copy pair specified in
the Copy Group Pair
Status panel
The following volume online
information is displayed to
4
the right of DEVN:
*: Online
-: Offline
Nothing is displayed when
volume online information
cannot be obtained.
2, 5
Copy pair status
Copy direction in the copy
pair
Storage system serial
number of the volume that
makes a copy pair
SSID of the volume that
makes a copy pair
CU number of the volume
that makes a copy pair
CCA of the volume that
makes a copy pair
Device number of the volume
that makes a copy pair