Function
This is a TSO/E command called from REXX scripts.
This command acquires the FlashCopy information related to the specified volume from the storage
system, and stores the information into the FlashCopy information structure that was specified by
the STEM parameter.
If the specified volume is not found, or an I/O error occurred and the storage system information
cannot be acquired, this command creates an error message in the command return configuration
structure, and then returns a return code other than 0.
This command can be used for volumes of the following models on which FlashCopy Mirror Version
2 is installed:
HP XP12000/XP10000 Disk Array
HP XP24000/XP20000 Disk Array
HP P9500 Disk Array
Parameters
STEM(stem-name- 1 ) ~ <REXX prefix of 64 or fewer characters>
Specify an optional prefix for the name of the FlashCopy information structure used to store the
FlashCopy information. You must also include a trailing period character.
MSG(stem-name-2) ~ <REXX prefix of 64 or fewer characters>
Specify an optional prefix for the name of the message structure used to store the messages to be
generated by this command. You must also include a trailing period character.
The message structure is initialized when the CLI command with the same name as the MSG
parameter is called.
DEVN(device-number) ~ <4-digit hexadecimal number>
Specify a device number for the volume from which the FlashCopy information will be acquired.
This parameter can be specified for locally connected devices only. It cannot be specified for Non
Gen'ed volumes.
Return Codes
Table 109 (page 211)
Table 109 YKFCSTAT Command Return Code List
Return Code
Meaning
-4095 to -4040
The command terminated abnormally. A possible cause is as follows:
The module cannot be loaded. Possible causes are as follows:
-3
An interruption occurred during execution.
-1
The command completed normally.
0
32
An error occurred while a REXX variable was being written.
40
lists the return codes to be returned when the YKFCSTAT command terminates.
The user SVC routine has not been included properly.
The library dataset has not been linked.
The module is protected by the RACF program control function.
I/O errors were encountered.
A change in an I/O configuration definition was detected.
Command details