HP Cisco MDS 9216 - Fabric Switch Configuration Manual page 1258

Cisco mds 9000 family fabric manager configuration guide, release 3.x (ol-8222-10, april 2008)
Hide thumbs Also See for Cisco MDS 9216 - Fabric Switch:
Table of Contents

Advertisement

Analyzing End-to-End Connectivity
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Analyze the redundant paths between endpoints by checking the Ensure that redundant paths exist
Step 6
between members check box.
Step 7
Check the Report errors for check box to see a report of zone and device errors.
Click Analyze.
Step 8
The End to End Connectivity Analysis window displays the selected endpoints including the switch to
which each is attached, and the source and target ports used to connect it, as shown in
Figure 68-3
The output shows all the requests that have failed. The possible descriptions are:
Ignoring empty zone—No requests are issued for this zone.
Ignoring zone with single member—No requests are issued for this zone.
Source/Target are unknown—No name server entries exist for the ports or we have not discovered
the port during discovery.
Both devices are on the same switch.
No paths exist between the two devices.
VSAN does not have an active zone set and the default zone is denied.
Cisco MDS 9000 Family Fabric Manager Configuration Guide
68-6
Results of an End-to-End Connectivity Analysis
Chapter 68
Troubleshooting Your Fabric
Figure
OL-8007-10, Cisco MDS SAN-OS Release 3.x
68-3.