Interface Nonoperational Reason Codes - HP Cisco MDS 9216 - Fabric Switch Configuration Manual

Cisco mds 9000 family fabric manager configuration guide, release 3.x (ol-8222-10, april 2008)
Hide thumbs Also See for Cisco MDS 9216 - Fabric Switch:
Table of Contents

Advertisement

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Interface Nonoperational Reason Codes

If the administrative state for an interface is up and the operational state is down, the reason code differs
based on the nonoperational reason code as described in
Table C-1
Reason Code
Link failure or not connected
SFP not present
Initializing
Reconfigure fabric in progress The fabric is currently being reconfigured.
Offline
Inactive
Hardware failure
Error disabled
OL-8007-10, Cisco MDS SAN-OS Release 3.x
Reason Codes for Nonoperational States
Description
Physical layer link is not operational.
The small form-factor pluggable (SFP) hardware is not
plugged in.
The physical layer link is operational and the protocol
initialization is in progress.
Cisco MDS SAN-OS waits for the specified R_A_TOV
time before retrying initialization.
The interface VSAN is deleted or is in a suspended
state.
To make the interface operational, assign that port to a
configured and active VSAN.
A hardware failure is detected.
Error conditions require administrative attention.
Interfaces may be error-disabled for various reasons.
For example:
Configuration failure.
Incompatible buffer-to-buffer credit configuration.
To make the interface operational, you must first fix the
error conditions causing this state; and next,
administratively shut down or enable the interface.
A P P E N D I X
Table
C-1.
Cisco MDS 9000 Family Fabric Manager Configuration Guide
C
Applicable
Modes
All
C-1

Advertisement

Table of Contents
loading

Table of Contents