AT&T MERLIN LEGEND Installation & Maintenance Manual page 526

Hide thumbs Also See for MERLIN LEGEND:
Table of Contents

Advertisement

Maintenance and Troubleshooting
Table 5-2 Continued
Error
Screen
Code
Description
000D
FMWR NOT
IN STANDBY
MODE
000E
COMMAND
BUFFER
FULL
000F
TASK
RUNNING
TOO LONG
0010
INVALID
SLOT
INTERRUPT
0011
STACK
OVERFLOW
0012
INVALID
RESET FLAG
0013
DUART
STREAMING
INT
0014
PROCESSOR
ERR
INTERRUPT
0015
MODULE
MISMATCH
0C01
NO I-VMS
PORT IN
SERV
5-48 Troubleshooting
Possible Cause
Module firmware is
not in standby mode
at cold start.
Module failure
Faulty processor
module
Faulty processor
module
System cannot
determine module
responsible for
generating interrupt
Faulty processor
module
Faulty processor
module
Faulty processor
module
Faulty processor
module
Module inserted into
wrong slot, and
physical and logical
types do not match
All VMS ports are out
of service.
Solution
If problem persists,
check or replace
module.
No action is needed. If
problem persists, check
or replace module.
No action is needed. If
problem persists, check
or replace processor
module.
Check modules and
replace if necessary. If
problem persists, check
or replace processor
module.
Check or replace
processor module.
Check or replace
processor module.
Check or replace
processor module.
Check or replace
processor module.
Change programming
to reflect proper module
or install proper
module.
No action is needed.