Altigen AltiWare ACC 5.2 Administration Manual page 196

Table of Contents

Advertisement

Chapter 15: Extension Configuration
(Ext. 101 using 1012, 9101, 10101, and so on) are not allowed. The letters map
to numbers as follows:
Numbers
2
3
4
5
DID Number—Each extension can be assigned a DID number. This number does
not have a fixed length, but the length must be long enough (range 2–16) for the
system to match the DID incoming call.
If you configure a 10-digit DID number and inbound digital trunks only receive 4
digits, the last 4 digits of the DID number configured will be matched.
Transmitted CID—Each extension number can be assigned a caller ID number.
When an outgoing call is made by this extension through PRI or IP trunks, the caller
ID number entered in this field will be transmitted to the receiving caller.
When an extension user makes an outbound call through a PRI trunk, the system
will transmit the Caller ID based on the following rules:
If the Transmitted CID is configured, the number will be sent.
If the Transmitted CID is not configured, the DID number will be sent if it is a valid
10-digit number.
If the DID number is not configured or not valid, the Area Code and Phone
Number entered in the Trunk Configuration window will be sent.
If the Area Code and Phone Number are not configured in the Trunk
Configuration window, the System Main Number in the System Configuration
window will be sent.
These rules may be overridden by your PRI CID configuration.
Note:
E911 CID—A number entered in this field will be transmitted as the caller ID for 911
calls made by this extension.
If a number is not entered in the E911 CID field, the Transmitted CID is
Note:
transmitted as the caller ID for 911 calls made by this extension.
Description—Optional descriptive information such as cubicle number or job title.
Language—Sets the language the extension user will hear for voice mail and
system prompts. If voice mail and system phrases have been translated into other
languages and properly added to the C:\PostOffice\Phrases directory, the languages
will be selectable from the Language drop-down list. (See "Multilingual
Configuration" on page 91 for information on adding translated prompts to the
AltiWare system).
Feature Profile—Sets an extension feature profile that includes enabling or
disabling of extension features. The feature profile must first be configured by the
administrator on the Feature Profiles tab of System Configuration (see "Feature
Profiles" on page 77).
Enable Dial-By-Name—Select this box to allow incoming callers to search the
extension list by employee name for this extension.
184
AltiWare ACC 5.2 Administration Manual
Letters
Numbers
A, B, C, a, b, c
6
D, E, F, d, e, f
7
G, H, I, g, h, i
8
J, K, L, j, k, l
9
Letters
M, N, O, m, n, o
P, Q, R, S, p, q, r, s
T, U, V, t, u, v
W, X, Y, Z, w, x, y, z