Chapter 12: Trunk Configuration
Parameter
Caller ID and DID Collection
You can select the maximum time-out delays, in seconds, and the appropriate
sequence of symbols to be collected for Caller ID and DID.
Max. seconds
before the first
digit
Max. seconds
between digits
Incoming
sequence
Or
Apply to
In order for back-to-back T1 and tie trunk T1 configurations to perform properly,
Note:
it is recommended that you use the system's default incoming call sequences:
146
AltiWare ACC 5.2 Administration Manual
Description
Maximum wait time before time-out for the system to identify
this digit after either the first ring in ground start or loop start
or the wink in wink start. The range is from 1-6 seconds, or
None, with a default value of 3 seconds. Do not change this
value unless advised.
None means no Caller ID or DID information will be collected.
All other options will be grayed out. Use this option to disable
Caller ID and DID collection.
Maximum wait time before time-out between two digits.
Default value is None. Do not change this value unless
advised.
Selecting None means the system will only wait for the
sequence of digits that are collected within the length of time
specified in the Max. seconds before the first digit field.
Select up to five incoming symbols to collect from the Caller
ID or DID digits:
None
#
*
# or *
Caller ID
DID/DNIS
Selecting None in any field of the sequence will terminate the
sequence and automatically disable subsequent entries in the
sequence.
The default sequence is:
"# or *" (and then) "Caller ID" (and then) "# or *" (and then) "DID/
DNIS"
Sets up an additional, alternative sequence. You can select
another set of up to five incoming symbols to collect.
Not checking any box is equivalent to checking None in the
first field.
The default sequence is:
"DID/DNIS"
If appropriate, you can use this button, as described in
"Configuring One or Multiple Trunks" on page 137, to apply
the Caller ID Collection to multiple T1 trunks.