debug ktrace show
Displays current kTrace parameters (e.g., kTrace status, Application IDs with non-default Severity Level
settings).
debug ktrace show
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6624, 6648, 7700, 7800, 8800
Usage Guidelines
N/A
Examples
-> debug ktrace show
kTrace is:
- INITIALIZED
- RUNNING
- configured to TRACE CALLERS
All applications have their trace level set to the level 'info' (6)
Output fields are described here:
output definitions
Application ID
Level
Release History
Release 5.1; command was introduced.
page -202
If an Application ID (subsystem) keyword is displayed, such as SNMP
(68), its Severity Level is not set to the info (6) default setting.
The Severity Level of the above-referenced Application ID. Levels
include off (1), alarm (2), error (3), alert (4), warning (5), info (6),
debug1 (7), debug2 (8), and debug3 (9).