Alcatel OmniSwitch 6624 Troubleshooting Manual page 565

Alcatel internetworking, inc. switch troubleshooting guide
Hide thumbs Also See for OmniSwitch 6624:
Table of Contents

Advertisement

debug systrace show
Displays sysTrace debug log information (e.g., sysTrace status, Application IDs with non-default Severity
Level settings).
debug systrace show
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6624, 6648, 7700, 7800, 8800
Usage Guidelines
N/A
Examples
-> debug systrace show
sysTrace is:
- INITIALIZED
- RUNNING
- configured to TRACE CALLERS
- configured to NOT WATCH on stdout
Only applications not at the level 'info' (6) are shown
Application ID
--------------------------------------------------------
SNMP
(68)
MIPGW
(70)
SYSTEM
(75)
Output fields are described here:
output definitions
Application ID
Level
Release History
Release 5.1; command was introduced.
OmniSwitch Troubleshooting Guide
Level
debug 1
(7)
debug 1
(7)
debug 3
(9)
The Application ID (subsystem) for which the Severity Level is not set
to the info (6) default setting.
The Severity Level of the above-referenced Application ID. Levels
include off (1), alarm (2), error (3), alert (4), warning (5), info (6),
debug1 (7), debug2 (8), and debug3 (9).
September 2005
page -179

Hide quick links: