CS1D Reference Manual (Hardware)
Hint
In the UTILITY function PREFERENCE screen you
can specify whether the GR meter display will be
linked with the compressor on/off setting. If linking
is on, the GR meter will be displayed only when the
compressor is on; the meter will not be displayed
when the compressor is off. If linking is turned off,
the GR meter will always be displayed.
8 COMPRESSOR [POST] meter LEDs
This meter indicates the signal level after the com-
pressor.
9 COMPRESSOR [PRE CLIP] LED
This LED will light if the signal clips before passing
through the compressor.
0 COMPRESSOR [LINK] switch and LED
This specifies whether compressor operation of adja-
cent odd-numbered
nels will be linked by a key-in signal (link=on) or
whether the compressors will operate using indepen-
dent key-in signals (link=off). (The LED will light
when link is on.)
Key-in signal flow when link=on
LINK = ON
THR
Key-in signal of odd-
numbered channel
THR
Key-in signal of even-
numbered channel
Key-in signal flow when link=off
LINK = OFF
THR
Key-in signal of odd-
numbered channel
THR
Key-in signal of even-
numbered channel
Linking will occur only if channels of the same
COMPRESSOR type are linked. If channels with
differing types are linked, the operation will be the
same as if link is off.
Be careful not to confuse "compressor linking" with
"input channel pairing."
Turning compressor link on will simply cause the
two compressors to be triggered by the same key-in
signal; the parameters of the compressors them-
selves can be set independently for each channel.
If two input channels are paired, compressor link
will automatically be turned on, and the compres-
sor parameters will also operate in tandem.
However, you are free to subsequently turn linking
off.
For a ST IN channel, the compressor parameters for
the left and right channels will always operate in
tandem. However, you are free to turn link on/off.
26
even-numbered input chan-
ATTACK
Detect the
processing
maximum
level
ATTACK
processing
Detect the
ATTACK
maximum level
processing
Detect the
ATTACK
processing
maximum level
A COMPRESSOR [ON] switch and LED
This switch turns the internal compressor on/off.
When the compressor is on, the LED will light.
B COMPRESSOR [GAIN] encoder and LEDs
This encoder controls the GAIN parameter of the
internal compressor.
The approximate current value is shown by the
perimeter LEDs.
The value range is 0 dB– +18 dB (0.5 dB steps) when
the type is COMP/EXPANDER, and –18 dB–0 dB
(0.5 dB steps) when the type is COMPANDER.
C COMPRESSOR [THR] encoder and LEDs
This encoder controls the THRESHOLD LEVEL
parameter of the internal compressor.
The approximate current value is shown by the
perimeter LEDs.
The value range is –54 dB–0 dB (1 dB steps).
GR