SMC Networks E21011 User Manual page 153

802.11 a/b/g/n access point
Table of Contents

Advertisement

D
All traps enabled
C
Global Configuration
C
This command is used in conjunction with the snmp-server host and
snmp-server enable server commands to enable SNMP notifications.
E
This command configures SNMP v3 views. Use the no form to delete an
snmp-server vacm
SNMP v3 view or remove a subtree from a filter.
view
S
D
None
sntpServerFail - The access point has failed to set the time
from the configured SNTP server.
sysConfigFileVersionChanged - The access point's
configuration file has been changed.
sysRadiusServerChanged - The access point has changed
from the primary RADIUS server to the secondary, or from the
secondary to the primary.
sysSystemDown - The access point is about to shutdown and
reboot.
sysSystemUp - The access point is up and running.
S
EFAULT
ETTING
M
OMMAND
ODE
U
OMMAND
SAGE
XAMPLE
AP(config)#no snmp-server trap dot11StationAssociation
AP(config)#
YNTAX
snmp-server vacm view <name> [included | excluded] <subtree>
[mask <mask>]
no snmp-server vacm view <name> [included | excluded]
<subtree>
name - A user-defined name that identifies an SNMP v3 view.
(Maximum length: 32 characters)
include - Defines a filter type that includes objects in the MIB
subtree.
exclude - Defines a filter type that excludes objects in the MIB
subtree.
subtree - The part of the MIB subtree that is to be filtered.
mask - An optional hexadecimal value bit mask to define objects in
the MIB subtree.
S
EFAULT
ETTING
– 153 –
| SNMP Commands
C
17
HAPTER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eliteconnect smce21011

Table of Contents