IBM 3745 Problem Determination Manual page 76

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
Alerts
3745 Alert Reference Code OA
Alert Condition: An unrecoverable error was detected by MOSS microcode when in use with the local
console. The MOSS is suspected as the cause of the problem.
ALARM OA : MOSS-TO-LOCAL CONSOLE TRANSMISSION ERROR
~
NelView' Alert - Dynamic
Local Console Error: MOSS
Subvector and
Code
Subfield Keys
Points
Alert
10
Number
SV X'92'
-,
Alert Type
X'01 '
SV X'92'
Alert Description
X'1301'
SV X'92'
Probable Causes
X'OOO1'
SV X'93'
X'6315'
User Causes
(none)
SV X'94' SF X'01'
Install Causes
(none}
SV X'95' SF X'01'
Failure Causes
X'330j:'
SV X'96' SF X'01'
X'3400'
X'6350'
Actions
X'0301 '
SV X'96' SF X'81'
X'0401'
X'0402'
X'3303 '
X'3000 '
X'32CO'
X'82 '
SF
X'82'
SF
Causes and Actions
X' BD7C213F'
Permanent
Local Console Error
MOSS
Console
Console Adapter
Cable Loose or Defective
Local Console
Check Cable and its connections ,
Run Console Test
Run Console Link Test
If unsuccessful then do the following
Contact Appropriate Service Representative
Report the following:
(Reference Code (x'30'))
. (Product Alert Reference
Code~(x'FO'))
Ch~pter 1. Alarms and -Aler,t,s.
1-59