IBM 3745 Problem Determination Manual page 184

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
3745 Alert Reference Code 09
Alert Condition: An IPL of the control program is going to occur soon.
The elapsed time between the receipt of this alert and the IPL has been specified in the NOTIFY
keyword of the VTAM 'MODIFY LOAD' command.
To obtain the full benefit of NetView alerts, Network Problem Determination Application (NPDA), also
referred to as NetView Hardware Monitor Facility, can be used to monitor all alerts displayed. The
NetView Automation Table can be updated to recognize the Timed IPL Alert and generate an
appropriate message. (No alert is displayed if the The NetView Automation Table is not updated.)
MOSS Console Alarm Message - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
ALARM 09 : CCU-x TIMED IPL TO OCCUR IN hh:mm CHECK VALIDITY
NetView Alert - Dynamic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
TIMED IPL TO OCCUR SOON: NETWORK OPERATOR
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X'C8C275DF'
SV X'92'
Alert Type
X'11'
Impending
SV X'92'
Alert Description
X'BOOA'
Timed IPL to occur soon
SV X'92'
Probable Causes
X'7003'
Network operator
SV X'93'
User Causes
X'7006'
Network operator
SV X'94' SF X'01'
Actions
X'3110'
Contact Communications Systems Programmer
SV X'94' SF X'81'
X'FOAO'
For:
X'82'
SF
(Communication Control Unit (X'34'))
X'0170'
Verify impending event should occur
X'01A1'
Verify:
X'82'
SF
(Time hh:mm (X'91'))
X'32AO'
Report the following:
X'82'
SF
(Product alert reference code (X'FO')) '09'
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
(none)
SV X'96' SF X'01'
Chapter 1. Alarms and Alerts
1-167