Alarms • Alarms
List of Alarms
ALARM 01: MOSS TRANSIENT ERROR.
hhmmss ref code
Note: The corresponding alert is not displayed on the NetView· console if the control program is not
loaded.
Cause:
MOSS hardware
Action:
• Refer to the NCP, SSP, and EP Diagnosis Guide.
• If the problem recurs:
CO
and give reference code.
ALARM 02: MOSS TRANSIENT ERROR. DUMP
hhmmss ref code
Note: The corresponding alert is not displayed on the NetView· console if the control program is not
loaded.
Cause:
Action:
MOSS hardware
MOSS microcode
• Transfer the MOSS damp to the host and print it. Refer to the NCP, SSP, and EP
Diagnosis Guide.
• If the problem recurs:
CO
and give reference code.
ALARM 04: MOSS DISK ADAPTER ERROR
hhmmss ref code
Note: The corresponding alert is not displayed on the NetView· console if the control program is not
loaded.
Cause:
Action:
Disk adapter
Disk drive
Internal power unit
• Re-IMl MOSS from disk at the control panel.
-
If unsuccessful:
CO
and give reference code and'control panel hex code.
• Perform disk file error recovery procedures:
Re-IML in diskette mode (the next IPL will be performed from the diskette).
If the problem persists:
CO
and give reference code and control panel hex code.