IBM 3745 Problem Determination Manual page 31

Communication controller
Table of Contents

Advertisement

ALARM 33: CP ERROR: ELAyy (PORT 1·2) RE·IML COMPLETE
Cause:
. Control program
Local CSMAlCD adapter (microcode)
Action:
Reactivate resources attached to the adapter.
• If the problem reoccurs:
-
Check if NCP is at the right level.
-
Check for correct software fix.
• If the problem persists:
Take a communication line trace.
Take a NCP dump.
hhmmss ref code
ra
the software support arid give the reference code of the previous alarm 32.
ALARM 34: HARDWARE ERROR: ELAyy (PORT 1·2) RE·IML IN PROGRESS
hhmmss ref code
Cause:
Action:
Local CSMA/CD adapter (hardware)
Wait for additional message before taking action.
If the problem persists or occurs repeatedly,
ra
the hardware support and give the
reference code.
ALARM 35: TRANSIENT HOW ERROR: ELAyy (PORT 1;.2) RE·IML COMPLETE
hhmmss ref code
Cause:
Action:
Local CSMA/CD adapter (hardware)
• Reactivate the resources attached to the ELA.
• If the problem reoccurs,
ra
the hardware support and give the reference code of the
previous alarm 34.
ALARM 36: PERMANENT HOW ERROR: ELAyy (PORT 1·2) RE·IML FAILED
hhmmss ref code
Cause:
Local CSMf'ICD adapter (hardware)
Action:
ra
the hardware support and give the reference code of the previous alarm 34 .
1-14
IBM 3745 Communication Controller: Problem Determination Guide
o