IBM 3745 Problem Determination Manual page 144

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
Alerts
3745 Alert Reference Code 89
Alert Condition: The control program sent an input/output command to a token-ring adapter thatis not
installed.
MOSS Console Alarm Message - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
ALARM 89 : TOKEN RING ADAPTER NOT INSTALLED
NetView· Alert - Dynamic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
Software Program Error: Loc Token Ring Adpt
(Software Program Error: Local Token Ring Adapter)
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X
1
172FA558
1
SV X'92'
Alert Type
X
1
01 '
Permanent
SV X'92'
Alert Description
X
1
2100 '
Software Program Error
SV X'92'
Probable Causes
X
1
3320 '
Local Token-Ring Adapter
SV X'93'
User Causes
(none)
SV X'94' SF X'01'
Install Causes
X
1
1200 '
Incorrect hardware configuration
SV X'95' SF X'01'
X '1500 '
Mismatch between hardware and microcode
Actions
X
1
1503 '
Correct Configuration
SV X'95' SF X'81'
X
1
1500 '
Correct Installation Problem
X '3301'
If problem persists then do the following
X'3000'
Contact Appropriate Service Representative
X'32AO'
Report the following:
X'82'
SF
(Reference Code
(x'30'))
Failure Causes
X' 1021 '
Communication Controller Control Program
SV X'96' SF X'01'
-
Actions
X'3000'
Contact Appropriate Service Representative
SV X'95' SF X'81'
X'FOAO'
For
X'82'
SF
(Product Alert Reference Code (x'FO'))
Chapter 1. Alarms
and Alerts
1-127