o
o
ALARM 68: LA nn (LINES xxxx-yyyy) RE-IML COMPLETE. NO DUMP
hhmmss ref code
Cause:
Action:
Line adapter hardware
• Reactivate lines from the host and retry.
• If the problem recurs:
CO
and give the reference code of the preceding alarms
related to this one. To display the alarms, use the Event Log Display (ELD) function.
Refer to the 3745 Advanced Operations Guide.
ALARM 6A: LA nn (LINES xxxx-yyyy) IML FAILED. NO DUMP
hhmmss ref code
Cause:
Line Adapter
Action:
CO
and give reference code along with the reference code of the related alarm 01.
ALARM 68: LA nn (LINES xxxx-yyyy) RE-IML FAILED. DUMP
hhmmss ref code
Cause:
Line adapter microcode
MOSS microcode
o
Action:
o
o
• Transfer the line adapter dump to the host and print it. Refer to the NCP, SSP, and EP
Diagnosis Guide.
• Re-IML the line adapter using the IMS function. Refer to the 3745 Basic Operations
Guide. If the re-IML is successful, re-activate the lines from the host and retry.
• If the problem persists:
CO
and give reference code along with the reference code
of the related alarm 68.
ALARM 72: HPTSS (HSS xx) HARDWARE FAILURE
hhmmss ref code
Cause:
Action:
HPTSS adapter
Storage control
CO
and give reference code.
Chapter 1. Alarms and Alerts
1-25