IBM 3745 Problem Determination Manual page 51

Communication controller
Table of Contents

Advertisement

ALARM 90: CCU-x POWER SUPPLY DOWN
hhmmss ref code
Cause:
Power supply
Action:
• Restore power supplies using the Power Services function (POS).
Refer to the 3745 Advanced Operations Guide.
• If the problem persists,
CO
and
~ive referenc~
code.
ALARM 95: FIRST TEMPERATURE THRESHOLD REACHED ON CCU-x
Cause:
Action:
Air filter _
Thermal detector
Cooling fan
Power supply
Power control
hhmmss ref code
• Check that
~ir
vents are not obstructed and that the room temperature is correct.
• Check for dirty filter.
• If the problem persists,
CO
and give reference code.
ALARM 96: POWER SUBSYSTEM: CCU POWER SUPPLY OVERHEATING
Cause:
Action:
Power s-upply
Power control
CO
and give reference code.
1-34
IBM 3745 Communication Controller: Problem Determination Guide
h",mmss ref code
o
, r \
\~-.)
o

Advertisement

Table of Contents
loading