Communication controller
Table of Contents

Advertisement

Alerts
o
3745 Product Alert Reference Code A2
Alert Condition: The power control unit can no longer monitor the power supplies on a power bus.
MOSS 'Console Alarm message
-----~---------------------,
ALARM
A2 :
POWER SUPPLY-TO-POWER CONTROL ERROR
(:M9:~:~j!'.:~~9i~:·~1,9:~:::~"9~~:~~19a
NetView· Alert - Dynamic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
Device Error: Internal Power Control Unit
o
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X '2AOF49FD
I
SV X'92'
Alert Type
X
1
01
1
Permanent
SV X'92'
Alert Description
X ' 1002
1
Device Error
o
SV X'92'
Probable Causes
X ' 0202 1
Internal Power Control Unit
SV X'93'
User Causes
(none).
SV X'94' SF X'01'
-
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
X ' 0202 1
Internal Power Control Unit
SV X'96' SF X'01'
X ' 0203 1
Power Cable
o
X ' 0201 1
Internal Power Unit
X ' 0205 1
Power SubSystem Processor
Actions
X 13000 1
Contact Appropriate Service Representative
SV X'96' SF X'81'
X ' 32CO'
Report the following:
X ' 82
1
SF
(Reference Code (x'30'))
X ' 82
1
SF
(Product Alert Reference Code (x'FO'))
o