3745 Product Alert Reference Code 04
Alert Condition: In twin-standby mode, following the IPL of the running CCU, the standby CCU was
tested and IPLed ready for immediate fallback. A minor or non-disrl;lptive error related to the MOSS
adapter has been encountered.
ALARM 04 : IPL OF STANDBY CCU-x COMPLETE WITH ERRORS
[M.9.·~:~:I:~:::t19.~:::~jg:1
G
NetView' Alert· Dynamic
Adapter Error: MOSS
Subvector and
Cod~
Subfield Keys
Points
Alert ID Number
SV X'92'
Alert Type
X 1 01 1
SV X'92'
Alert Description
X
I
1010 1
SV X'92'
Probable Causes
X 100011
SV X'93'
User Causes
(none)
SV X'94' SF X'01'
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
X 100011
SV X'96' SF X'01'
Actions
X ' 3000 '
SV X'96' SF X'81'
X ' 32DO '
X ' 82 1
SF
X ' 82 1
SF
X ' 82 1
SF
Causes and Actions
X 1 D3A63 E46 1
Permanent
Adapter Error
MOSS
MOSS Hardware
Contact Appropriate Service Representative
Report the following:
(Communication Control Unit (x'34'))
(Reference Code (x'30'))
(Product Alert Reference Code (x'FO'))
Chapter 1. Alarms and Alerts