Timed IPL Alarms and Ale'rt • Timed IPL Alarms and Alert
Timed IPL Alarms and Alert
ALARM 08: cCU-x LM= xxxxxxx: TIMED IPL CANCELLED
hhmmss ref code
Cause:
Action:
• The battery is down.
• The scheduled IPL date and time is passed for this load module (or for one of the load
modules in the case of 'multiple load module')
• At the scheduled IPL time the MOSS status did not allow for an automatic IPL, MOSS
must be online.
• Check if there is also the associated alarm:
AS: ASK SERVICE PERSONNEL TO REPLACE BATTERY
In this case,
CO
to have the MOSS battery replaced.
• Check the status of the MOSS and use the
Oil
function to check the timed IPL
information.
Refer to Guide to Timed IPL and Rename Load Module, SA33-017B.
Use the appropriate VTAM command to restart the operations.
Note: The alarm DB is not generated on receipt of the following VTAM commands from the host:
• IPL (with the option SAVE) which replaces a load module for which timed IPL was set.
• Modify Load Module command (MLM) for cancelling a timed IPL.
• Modify Load Module command (MLM) for replacing or purging a load module for which
timed IPL was set.
ALARM '09: CCU-x TIMED IPL TO OCCUR IN hh:mm CHECK VALIDITY
hhmmss
ref code
Cause:
Action:
Network operator
No action if the IPL time, mentioned with the alarm, corresponds to the scheduled IPL time;
otherwise, if the time does not correspond, contact the network operator for investigation.
1-166
IBM 3745 Communication Controller: Problem Determination Guide