3745 Alert Reference Code 80
Alert Condition: There has been an input/output error at the local token-ring-adapter level at
initialization time. All TICs connected to this adapter are affected.
MOSS Console Alarm Message - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
ALARM 80 : TRSS HARDWARE INITIALIZATION ERROR ON TRA xx
NetView· Alert - Dynamic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
Initialization Failure: Loc Token Ring Adpt
(Initialization Failure: Local Token Ring Adapter)
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
ID
Number
X'CA919DA1'
SV X'92'
Alert Type
X'01'
Permanent
SV X'92'
Alert Description
X'3210'
Initialization Failure
SV X'92'
Probable Causes
X'3320'
Local Token-Ring Adapter
SV X'93'
User Causes
(none)
SV X'94' SF X'01'
Install Causes
(none)
SV X'9S' SF X'01'
Failure Causes
X'3320'
Local Token Ring Adapter
SV X'96' SF X'01'
Actions
X'13A1'
Reactivate resources attached to
SV X'96' SF X'81'
X'82'
SF
(Line Adapter Number (x'63'))
X'3300'
If problem re-occurs then do the following.
X'3000'
Contact Appropriate Service Representative
X'32CO'
Report the following:
X'82'
SF
(Reference Code (x'30'))
X'82'
SF
(Product Alert Reference Code (x'FO'))
X'2203'
Review supporting data at Alert Sender