Looking at the host console:
If
A message at the host console indicates
an unsuccessful loading or activation of
the remote control program
(load/activation from the host).
Do
1. On the local 3745
• An alarm is displayed at the MOSS console.
If the alarm is related to the problem, perform the action required for that alarm (see
Chapter 1).
2. On the remote 3745
• An alarm is displayed at the MOSS console.
If the alarm is related to the problem, perform the action required for that alarm (see
Chapter 1).
Note the hex code on the control panel, go to Chapter 3 and perform,the action
required for that code.
Check the I PL port· configuration on the
3745.
Refer to the MOSS LKP function of the
3745 Advanced Operations Guide.
Re-IPL the remote 3745. Wnenthe control pan.el displays the hexcode FF4, do not
load the control program.
From the host, Using a VTAM command, get a dump of the remote control program.
If the parameters are incorrect, correct them, otherwise
CO
with the reference code.
• No alarm is displayed at the MOSS console.
If you are performing a remote loading/activation (RLA) procedure, to help you in
solving your problem, you can refer to:
- "Remote Loading/Activation Overview" on page 8-10.
- "Remote Loading/Activation Problems and Messages" on page 8-11.
- 3720/3745 Remote Loading/Activation Guide, SA33-0161 for detailed information.
Use the VTAM 'MODIFY LL2' command or the N,etView 'LL2' command (on a
nonswitched SDLC link) to test the link between the two NCPs.
-Refer to VTAM Operation or NetView Operation documentations for detailed
information.
Check at both ends of the link that:
- The link modem is powered on and operational (for example, not in test mode).
- The modem cable to the LlC has correct cable group, or part number, and is
plugged in at both ends.