1. Connect the AC adaptor.
2. Perform "Battery Recalibration".
You can operate your computer while the battery recalibration is in progress.
1. Click
(Start) -
2. Click [OK] on "Perform Battery Recalibration after shutting down Windows." screen.
3. Click [OK] on "Windows will be shut down. OK?" screen.
4. Restart the computer, "Battery Recalibration Utility" is displayed.
5. Press ≪ Enter≫ .
6. When the confirmation message appears, select [Yes] and press ≪ Enter≫ .
After the battery recalibration is finished, normal charging starts.
NOTE
When this computer is driven by USB Power Delivery, the battery recalibration cannot be performed.
l
The temperature range should be 10 °C to 30 °C {50 °F to 86 °F}.
l
Frequent recalibration of the battery can degrade the battery. A caution message appears when the battery recalibration is
l
performed at the shorter interval than approximately a month. In this case, cancel the battery recalibration.
The battery recalibration may take a long time due to the large battery capacity. This is not a malfunction. (An expected
l
approximate recalibration time is displayed.)
If the computer is turned off during the battery recalibration (e.g., due to power failure, or accidental removal of the AC
l
adaptor and battery pack), the battery recalibration will not be completed.
<Only for model with Built-in Bridge Battery>
l
The battery recalibration cannot be performed for the built-in bridge battery.
<When performing "Battery Recalibration" after shutting down Windows>
l
FZ-VZSU1TU series
Full charge
Approx. 2.5 hours
FZ-VZSU1UU/FZ-VZSU1VU series
Full charge
Approx. 3.0 hours

Battery duration

Note that the computer consumes electricity even when the computer power is off. If the battery pack is fully charged, the battery will fully discharge in the
following period of time:
FZ-VZSU1TU series
In modern standby (sleep)
When entering into hibernation automatically after 16 hours (factory
default)
In modern standby (sleep)
When not entering into hibernation
(Panasonic PC Settings Utility) -
Complete discharge
Approx. 3.5 hours
Complete discharge
Approx. 5.0 hours
Status
(Support) -
(Battery) - [Perform battery recalibration].
Power On by
Only for model with keyboard
LAN
Deny
Approx. 4 weeks
Deny
Approx. 3.5 days
Discharge period
For tablet
base
Approx. 5.5
weeks
Approx. 4.5 days