Command Generation Axis Monitor Data - Mitsubishi Electric MELSEC iQ-R RD78G4 User Manual

Hide thumbs Also See for MELSEC iQ-R RD78G4:
Table of Contents

Advertisement

Command generation axis monitor data

n: Axis No. - 1
Monitor item
[Md.141]
BUSY
[Md.345]
Command generation axis accumulative
position value
[Md.347]
Command generation axis position value
per cycle
*1 Command generation axis position units (Page 38 Command generation axis position units)
[Md.141]BUSY
This signal turns ON at the start of positioning. It turns OFF when the "[Da.9] Dwell time/JUMP destination positioning data
No." has passed after positioning stops. (This signal remains ON during positioning.) This signal turns OFF at error
completion or positioning stop.
The BUSY signal turns ON even when position control of movement amount 0 is executed. However, since
the ON time is short, the ON status may not to be detected in the program.
[Md.345] Command generation axis accumulative position value
The accumulative position value for the command generation axis is stored in the "[Pr.1] Unit setting". The axis whose unit
setting is other than "degree" is set to "command position value = accumulative position value".
[Md.347] Command generation axis position value per cycle
The position value per cycle for the command generation axis is stored in the range from 0 to ("[Pr.346] Command generation
axis length per cycle" - 1).
2 INPUT AXIS MODULE
46
2.2 Command Generation Axis
Storage details
The BUSY status is stored.
Refresh cycle: Operation cycle
The accumulative position value for the
command generation axis is stored.
Refresh cycle: Operation cycle
The position value per cycle for the
command generation axis is stored.
Refresh cycle: Operation cycle
Monitor value
■Monitoring is carried out in decimal.
1: BUSY
Other than 1: Not BUSY
■Monitoring is carried out in decimal.
-2147483648 to 2147483647
[Command generation axis position units
■Monitoring is carried out in decimal.
0 to (Command generation axis length per
cycle - 1)
[Command generation axis position units
Buffer memory
address
61004+120n
61000+120n
61001+120n
*1
]
61002+120n
61003+120n
*1
]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r rd78g8Melsec iq-r rd78g16

Table of Contents