Mitsubishi Electric MELSEC iQ-R RD78G4 User Manual page 80

Hide thumbs Also See for MELSEC iQ-R RD78G4:
Table of Contents

Advertisement

■Coordinate data format
The coordinate data format is defined in coordinates of more than 2 points for one cam cycle. The coordinate data is
represented as "(Input value, Output value)".
Input value: Cam axis position value per cycle
Output value: Stroke position from cam reference position
With this format, "[Pr.441] Cam stroke amount" of output axis parameter is ignored and output value of the coordinate data
becomes cam stroke position.
Refer to the following for setting methods for cam data.
Page 82 Create Cam Data
Setting item
Setting details
Cam No.
Set the cam No.
Cam data format
Set "2".
(Setting with the engineering tool is not
required.)
Coordinate number
Set the number of coordinates to define the
cum curve for one cycle. The coordinates
at the 0th point are included.
Cam data starting
Setting is not required with coordinate data
point
format.
Coordinate data
Set all coordinate data (input value: X
output value: Y
Required to set the coordinate data (X
Y
The input value should be larger than the
previous coordinate data (X
Output value: Y
[Output axis position units]
2147483647
0
(X
,Y
)
0
0
(Cam reference
position)
-2147483648
When an input value that is 0 or the cam axis length per cycle does not exist in the coordinate data, the coordinate is
calculated from the line segment between the nearest two coordinates.
Output value: Y
[Output axis position units]
Generated line
segment from
(X0, Y0) and (X1, Y1)
2147483647
(X
,Y
0
0
(Cam reference
position)
-2147483648
3 CAM FUNCTION
78
3.1 Control Details for Cam Function
).
n
) from the 0th point.
0
< X
n
n + 1
(X
,Y
)
3
3
(X
,Y
4
(X
,Y
)
2
2
(X
,Y
)
1
1
Cam axis length per cycle [Cam axis cycle units]
(X
,Y
)
3
3
(X
,Y
4
(X
,Y
)
2
2
(X
,Y
)
1
1
)
0
Cam axis length per cycle [Cam axis cycle units]
Setting range
0: Linear cam
1 to 256: User created cam
2: Coordinate data format
2 to 16384
,
Input value:
n
0 to 2147483647
,
[Cam axis cycle units]
0
Output value:
-2147483648 to 2147483647
).
[Output axis position units]
)
4
(X
,Y
)
10
10
(X
,Y
)
5
5
(X
,Y
)
9
9
(X
,Y
)
(X
,Y
)
6
6
8
8
(X
,Y
)
7
7
Generated line
segment from
(X9, Y9) and (X10, Y10)
)
4
(X
,Y
)
5
5
(X
,Y
)
9
9
(X
,Y
)
(X
,Y
)
6
6
8
8
(X
,Y
)
7
7
Default value
(Engineering tool)
1
2
2
0
Input value: X
(X
,Y
)
10
10
Input value: X
Cam data
operation function
[Cd.601]
Operation cam No.
[Cd.604]
Cam data format
[Cd.605]
Cam resolution/
coordinate number
[Cd.606]
Cam data starting point
[Cd.607]
Cam data value

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r rd78g8Melsec iq-r rd78g16

Table of Contents