Mitsubishi Electric MELSEC iQ-R RD78G4 User Manual page 105

Hide thumbs Also See for MELSEC iQ-R RD78G4:
Table of Contents

Advertisement

Setting item
Setting details
[Pr.428]
• Set the clutch smoothing method.
Auxiliary shaft
Fetch cycle: At operation start
clutch smoothing
(Synchronous control)
method
[Pr.429]
• For smoothing with a time
Auxiliary shaft
constant method, set the
clutch smoothing
smoothing time constant.
time constant
Fetch cycle: At operation start
(Synchronous control)
[Pr.430]
• For smoothing with a slippage
Slippage amount at
method, set the slippage amount
auxiliary shaft
at clutch ON.
clutch ON
Fetch cycle: At completion of the
condition (Turning clutch ON)
[Pr.431]
• For smoothing with a slippage
Slippage amount at
method, set the slippage amount
auxiliary shaft
at clutch OFF.
clutch OFF
Fetch cycle: At completion of the
condition (Turning clutch OFF)
*1 The range from axis 1 to 4 is valid in the 4-axis module, from axis 1 to 8 is valid in the 8-axis module, and from axis 1 to 16 is valid in the
16-axis module.
*2 Auxiliary shaft position units (Page 28 INPUT AXIS MODULE)
*3 Cam axis cycle units (Page 123 Units for the output axis)
[Pr.422] Auxiliary shaft clutch control setting
Set the ON and OFF control methods separately for the auxiliary shaft.
The clutch control setting can be changed during synchronous control, however, the setting "No clutch" (Direct coupled
operation) cannot be selected during synchronous control after already selecting another setting.
Refer to the following for operation details on the clutch control.
Page 108 Control method for clutch
■ON control mode
Setting value
0: No clutch (Direct coupled
operation)
1: Clutch command ON/OFF
2: Clutch command leading edge
3: Clutch command trailing edge
4: Address mode
5: High speed input request
Other clutch parameters are not applicable during direct coupled operation by setting "0: No clutch". "[Cd.405]
Auxiliary shaft clutch forced OFF command" and the change of the clutch control setting are ignored during
direct coupled operation.
Setting value
■Set in decimal.
0: Direct
1: Time constant method (Exponent)
2: Time constant method (Linear)
3: Slippage method (Exponent)
4: Slippage method (Linear)
5: Slippage method (Linear: Input value follow up)
■Set in decimal.
0 to 5000[ms]
■Set in decimal.
0 to 2147483647
[Auxiliary shaft position units
*3
units
]
■Set in decimal.
0 to 2147483647
[Auxiliary shaft position units
*3
units
]
Details
Execute direct coupled operation without clutch control.
The clutch is turned ON/OFF by the operation of "[Cd.403] Auxiliary shaft clutch command" ON/OFF. (Setting in the
OFF control mode are not applicable in this mode.)
The clutch is turned ON when "[Cd.403] Auxiliary shaft clutch command" passes the leading edge (from OFF to ON).
The clutch is turned ON when "[Cd.403] Auxiliary shaft clutch command" passes the trailing edge (from ON to OFF).
The clutch is turned ON when the reference address (the auxiliary shaft current value or the position value per cycle
after auxiliary shaft gear) reaches "[Pr.424] Auxiliary shaft clutch ON address".
The movement amount after passing through the ON address is calculated as the output movement amount of the
clutch based on the reference address passing through, thereby controlling the clutch with an accurate movement
amount.
The clutch is turned ON when the high speed input request [DI] turns ON.
Default
Buffer memory address
value
Axis 1 to axis 16
0
36446+200n
0
36447+200n
0
36448+200n
36449+200n
*2
, or cam axis cycle
0
36450+200n
36451+200n
*2
, or cam axis cycle
4 ADVANCED SYNCHRONOUS CONTROL
4.2 Auxiliary Shaft Module
4
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r rd78g8Melsec iq-r rd78g16

Table of Contents