Mitsubishi Electric MELSEC iQ-R RD78G4 User Manual page 79

Hide thumbs Also See for MELSEC iQ-R RD78G4:
Table of Contents

Advertisement

■Stroke ratio data format
The stroke ratio data format is defined in equal divisions for one cam cycle based on the cam resolution, and configured with
stroke ratio data from points within the cam resolution.
Refer to the following for setting methods for cam data.
Page 82 Create Cam Data
Setting item
Setting details
Cam No.
Set the cam No.
Cam data format
Set "1".
(Setting with the engineering tool is not
required.)
Cam resolution
Set the number of divisions for one cam
cycle.
Cam data starting
Set the cam data point corresponding to
point
"Cam axis position value per cycle = 0".
Stroke ratio data
Set the stroke ratio from the 1st to the last
point.
(The 0th point setting is not required. It is
always 0%.)
*1 To display the stroke ratio out of range 100%, select the "Simple Motion" of "Intelligent Function Module" and set "Yes" to the "Display
Extended Stroke of Cam Graph" on the "Options" window displayed by the menu bar of the engineering tool [Tool]  [Options].
Ex.
Cam resolution: 512
Stroke ratio[%] (Setting range: -214.7483648% to 214.7483647%)
100.0000000
0
(Cam reference position)
-100.0000000
At the 0th point
Setting range
0: Linear cam
1 to 256: User created cam
1: Stroke ratio data format
256/512/1024/2048/ 4096/8192/
16384/32768
0 to (Cam resolution - 1)
-2147483648 to 2147483647
[10
(-214.7483648 to 214.7483647%)
Cam axis length per cycle [Cam axis cycle units]
Default value
(Engineering tool)
1
1
256
0
0
-7
*1
%]
At the 512th point
(At the last point)
3.1 Control Details for Cam Function
Cam data
operation function
[Cd.601]
Operation cam No.
[Cd.604]
Cam data format
[Cd.605]
Cam resolution/
coordinate number
[Cd.606]
Cam data starting point
[Cd.607]
Cam data value
3 CAM FUNCTION
77
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r rd78g8Melsec iq-r rd78g16

Table of Contents