SmartCombi™ Service
In case of an error the electronic switches in a emergency mode automatically This function enabled
restricted operating with the HansDampf.
„Emergency program" is shown on display permanently.
Every program arises from a previous temperature sensor error message.
The message "emergency program" can be deleted by reset of electronic only.
Error message in the diagnosis
Core temp. probe defect
CT1-probe defect
CT2-probe defect
CT3-probe defect
CT4-probe defect
Temp. probe chamber 1 defect
Temp. probe chamber 1 defect (only
20.x)
Humidity sensor
Drain temp. probe defect

Overview of the emergency programs

The core temperature probe function is not available.
The core temp. probe is used as a chamber probe now. The
core temperature probe function is not available. Due the
position of the core temp. probe easy temperature
differences of the chamber temperature measurement are
possible.
The humidity control (Clima Monitor) ist deactivated.
The drain cooling changes in an emergency program
(Controlled by the pcb). An increased water consumption
arises from it.
Overview
Consequence
5