7.1 Emergency operation

INFORMATION

7.2 Nameplate

7.3 Cause of error and remedy

Error no.
Fault message displayed
694
• Cooking sensor defective
695
699
• Internal core temperature
sensor defective
700
714
716
94
In order to allows limited use in case of error, the unit has several
different emergency programs. Emergency operation is activated
automatically and displayed. After elimination of the error indicated, the
controls switch back into normal operation automatically. A reset is not
necessary.
Emergency programs handle the limited further operation of the appliance until
servicing. Deviating cooking results and temperature deviations are possible.
When contacting customer service, please always provide the following
data from the nameplate:
Serial number
(SN)
Type number
(TYP)
If a fault occurs during operation, the fault number and fault message
are displayed.
Description
The internal core temperature
sensor assumes the function of the
defective cooking chamber sensor.
The internal core temperature
sensor in the cooking chamber is
deactivated.
Operating instructions
Action
• Insert the internal core tempera-
ture sensor into its holder.
• This can lead to a different cook-
ing result.
• Contact customer service.
• If possible, use the external core
temperature sensor (optional).
• Select a different cooking pro-
gram.
• Contact customer service.