P0480; Troubleshooting - Yamaha XSR 900 2022 Service Manual

Hide thumbs Also See for XSR 900 2022:
Table of Contents

Advertisement

EAS20585

P0480

EAS33065

TROUBLESHOOTING

Item
Radiator fan motor relay: open or short circuit is detected. Normal signal is not received from the radi-
ator fan motor relay.
Fail-safe system
• Able to start engine
• Able to drive vehicle
Procedure
1. Connection of radiator fan motor relay coupler.
• Check the locking condition of the coupler.
• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
Is the coupler condition normal?
YES
→ Go to step 2.
NO
a. Connect the coupler securely or replace the wire harness.
b. Turn the main switch to "ON", and then check the DTC using the malfunction mode of the YDT.
Is it in the "Recovered" condition?
YES
→ Go to step 6, and complete the service.
NO
→ Go to step 2.
2. Connection of ECU coupler.
• Check the locking condition of the coupler.
• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
Is the coupler condition normal?
YES
→ Go to step 3.
NO
a. Connect the coupler securely or replace the wire harness.
b. Turn the main switch to "ON", and then check the DTC using the malfunction mode of the YDT.
Is it in the "Recovered" condition?
YES
→ Go to step 6, and complete the service.
NO
→ Go to step 3.
9-173