1
Turn the AMR OFF.
2
Place the Main Disconnect Switch in the OFF position.
3
Remove the User Connections area cover, the Right and the Left Skins. Refer to 6-11-1 Re-
moving and Replacing Skins on page 6-17 for more information.
4
Prepare the M12 A coded power cable by trimming excess length and then stripping insulation
to prepare it for ferrule attachment.
5
Insert the brown wire into the ferrule and crimp the ferrule using the crimper. Repeat for the
blue wire.
6
Connect the negative blue wire connector to the negative terminal in the Laser PWR connector
on the Connector Panel.
7
Connect the positive brown wire connector to the positive terminal in the Laser PWR connector
on the Connector Panel.
8
Connect the other end of the A coded M12 power cable to the A coded M12 power connector
on the rear of the Side Laser.
AMR (Autonomous Mobile Robot) MD-series Platform User's Manual (I681)
Connect Brown Wires