Maintenance instructions LA 60P-TUR
NOTE
Personal protective equipment (protective goggles, safety
shoes and gloves where necessary) must be used when
working on the device. Components with plastic parts must
be protected from impact (e.g. from tools) to prevent damage
to these components.
Intended use
This device is only intended for use as specified by the manu-
facturer. Any other use beyond that intended by the manufac-
turer is prohibited. This requires the user to abide by the rele-
vant project planning documents. Please refrain from
tampering with or altering the device.
The device is designed for a service life of 15 years. Mainte-
nance must be carried out as per the maintenance instructions.
Before the end of the intended service life and taking into ac-
count the current technical rules, the operator must carry out
an assessment regarding continued operation. Based on the
assessment, the operator must make a decision regarding con-
tinued operation, decommissioning or measures to be carried
out. If the assessment and any measures to be carried out are
not implemented before the end of the intended service life,
the device must be decommissioned.
www.glendimplex.de
Purpose
The air-to-water heat pump is to be used exclusively for the
heating and cooling of heating water. It can be used in new or
existing heating systems.
The heat pump is designed exclusively for outdoor installation.
The heat pump is suitable for mono energy and bivalent opera-
tion in outside air temperatures to -22°C.
Proper defrosting of the evaporator is guaranteed by maintain-
ing a heating water return temperature of more than 22°C dur-
ing continuous operation. The maximum water outlet tempera-
ture must not exceed 64°C and must be secured on the system
side so that, if the temperature is exceeded, all additional heat
sources are switched off safely.
The heat pump is not designed for the increased heat con-
sumption required when a building is being dried out. For this
reason, the additional heat consumption should be met using
special devices provided by the customer. For drying out a
building in autumn or winter, it is advisable to install a suitable
2nd heat generator (e.g. an electric heating element available as
an accessory).
In cooling operation, the heat pump is suitable for air tempera-
tures ranging from +10°C to +45°C.
It can be used for silent and dynamic cooling. The minimum
cooling water outlet temperature is +7°C.
NOTE
The device is not suitable for operation with a frequency
converter.