Dimplex LA 60P-TUR Maintenance Instruction page 51

Air-to-water heat pump for outdoor installation
Hide thumbs Also See for LA 60P-TUR:
Table of Contents

Advertisement

Maintenance instructions LA 60P-TUR
4.3.2.3Y-adapter
4.3.3 Measuring process
Loosen the Schrader cap nut and sealing cap on the switch box
Screw the Y-adapter on the Schrader valve, ensuring that the lock nut in the switch box does not come loose
www.glendimplex.de
4.3.2.4Smartphone with installed Testo app
A smartphone with the following system requirements is re-
quired to record the measured values:
iOS 8.3 or newer
Android 4.3 or newer
Bluetooth 4.0
The corresponding "testo Smart Probes App" is available to
download free of charge from Google Play (Android) or the App
Store (iOS).
Connect the vacuum pump and differential pressure gauge
to one end of the adapter each with a hose provided
Open the testo Smart Probes App and connect the differen-
tial pressure gauge with the smartphone via Bluetooth
In the menu (top left), select the application "Standard view"
452167.66.43-EN · FD 0008
English
EN-17

Advertisement

Table of Contents
loading

Table of Contents