2-1-3

Mounting

E5CC, E5CC-B, and E5CC-U
There are two models of Terminal Covers that you can use with the E5CC.
Waterproof packing
For the Wiring Socket for the E5CC-U, purchase the P2CF-11 or PG3A-11 separately.
Mounting to the Panel
(1) For waterproof mounting, waterproof packing must be installed on the Digital Controller.
Waterproofing is not possible when group mounting several Digital Controllers. The
E5CC-U cannot be waterproofed even if the Waterproof Packing is inserted.
(2) Insert the E5CC, E5CC-B, or E5CC-U into the mounting hole in the panel.
(3) Push the Adapter from the terminals up to the panel, and temporarily fasten the E5CC,
E5CC-B, or E5CC-U.
(4) Tighten the two fastening screws on the Adapter. Alternately tighten the two screws little by
little to maintain a balance. Tighten the screws to a torque of 0.29 to 0.39 N·m.
E5@C Digital Temperature Controllers User's Manual (H174)
E53-COV17
Adapter
Terminal Cover
(Sold separately.)
Panel
Adapter
*
The Terminal Cover is provided only with the
following models: E5CC-@@@@5M-@@@.
2 Preparations
E53-COV23
Terminal Cover*
2
2 - 9