Parameters
Characters
pfd5
Monitor/Setting Item 5
000
spd1
PV/SP No. 1 Display
Selection
spd2
PV/SP No. 2 Display
Selection
odsl
MV Display Selection
pvdp
PV Decimal Point
000
Display
pvst
PV Status Display
Function
svst
SV Status Display
Function
d.ref
Display Refresh Period
lcmt
LCT Cooling Output
*8
Minimum ON Time
cmoV
Move to Calibration
000
Level
*1
If the Manual MV Limit Enable parameter is set to ON, the setting range will be the MV lower limit to the
MV upper limit.
*2
The setting ranges are different for relay and voltage outputs (for driving SSR) and for linear current
outputs.
*3
This parameter can be set when the Program Pattern parameter is set to OFF, but the function will be
disabled.
*4
WR1 to WR8 are not displayed when the logic operation function is not used.
*5
With the E5CC-U, E5DC, or E5GC, if the control output is a linear current output, the control output can
be used as a simple transfer output. (The E5CC-U must be manufactured in May 2014 or later (version
2.2 or higher) and the E5DC must be manufactured in July 2014 or later (version 2.2 or higher).)
*6
You can select seconds (S) only for the E5DC and E5GC. (The E5DC must be manufactured in July 2014
or later (version 2.2 or higher).)
*7
You can select the status display message (WR) only for the E5DC and E5GC. (The E5DC must be
manufactured in July 2014 or later (version 2.2 or higher).)
*8
This parameter is not supported for E5CC, E5EC, and E5AC version 2.0 or lower.
*9
You can use this parameter only with the E5EC-PR@-8@@ or E5AC-PR@-8@@. (The Digital Controller
must be manufactured in August 2014 or later (version 2.2 or higher).)
E5@C Digital Temperature Controllers User's Manual (H174)
Setting (monitor) value
Same as Monitor/Setting Item 1.
0: Nothing is displayed.
1: PV/SP/Nothing displayed
2: PV/Nothing displayed/Nothing displayed
3: SP/SP (character display)/Nothing displayed
4: PV/SP/MV (valve opening for
Position-proportional Models)
5: PV/SP/Multi-SP No.
6: PV/SP/Soak time remain
7: PV/SP/Internal SP (ramp SP)
8: PV/SP/Alarm value 1
Same as PV/SP No. 1 Display Selection.
O: MV (Heating)
C-O: MV (Cooling)
OFF, ON
OFF: OFF
MANU: Manual
STOP: Stop
ALM1: Alarm 1
ALM2: Alarm 2
ALM3: Alarm 3
ALM4: Alarm 4
ALM: OR of alarms 1 to 4
HA: Heater alarm
*7
WR: Status display message
OFF: OFF
MANU: Manual
STOP: Stop
ALM1: Alarm 1
ALM2: Alarm 2
ALM3: Alarm 3
ALM4: Alarm 4
ALM: OR of alarms 1 to 4
HA: Heater alarm
*7
WR: Status display message
OFF, 0.25, 0.5, 1.0
0.1 to 1.0
−1999 to 9999
A Appendices
Display
Default
0
None
*6
None
4
0
None
o
c-o
,
0
None
off
on
,
ON
None
off
OFF
None
manu
stop
alm1
alm2
alm3
alm4
alm
ha
wr
off
OFF
None
manu
stop
alm1
alm2
alm3
alm4
alm
ha
wr
off, 0.25,
0.25
Second
0.5, 1.0
0.2
Second
0
None
Unit
A
A - 31