COOK I-flex
OPERATING INSTRUCTIONS
B.PRO Control control
electronics error
message
Extraction operation
is not working, On/Off
switch is switched on,
operation indicator LED
does not light up
Cause
"Close door" message is shown on the
display.
"Check charcoal filter" message is shown
on the display.
"Temperature alarm" message is shown
on the display.
"ION TEC error" message is shown on
the display.
"Power PCB comm error" message is
shown on the display.
"Interface PCB comm error" message is
shown on the display.
"Temperature sensor wire broken" mes-
sage is shown on the display.
Cause
Protection temperature sensors have
been triggered.
Fan or unit electrical system is defective.
Measure
Close cover on the odour filter box.
ª
Section "Closing the cover"
Check that there is a charcoal filter pad in the
odour filter box and that it is correctly inserted.
ª
Section "Inserting the charcoal filter pad"
Reset the temperature monitoring display.
ª
Section "Restarting the unit after the tempera-
ture sensors are triggered"
Check ION TEC for damage.
ª
Section "Removing and cleaning the ION TEC
(optional)"
Notify a centre authorised to carry out repairs.
ª
Chapter "Repairs"
Notify a centre authorised to carry out repairs.
ª
Chapter "Repairs"
Notify a centre authorised to carry out repairs.
ª
Chapter "Repairs"
Measure
Carry out required measures for starting up
extraction again.
ª
Section "Restarting the unit after the tempera-
ture sensors are triggered"
Notify a centre authorised to carry out repairs
in cases of visible damage.
ª
Chapter "Repairs"
Notify a centre authorised to carry out repairs.
ª
Chapter "Repairs"
65