B.pro Control Control Electronics Initial Installation; Connecting External Devices - B.Pro COOK I-FLEX 1 Translation Of The Original Operating Instructions

Table of Contents

Advertisement

COOK I-flex
OPERATING INSTRUCTIONS
B.PRO Control control
electronics initial
installation
Connecting external
devices
42
Caution!
Damage to the unit electrical system and customer-supplied socket outlet
If connected external units have not been switched off before plugging in or unplugging the
mains plug, the unit electrical system and customer-supplied socket outlet may become dama-
ged.
– Before connection, ensure that connected external units are switched off.
– Connect the mains plug to the socket outlet.
"Unit On/Off" button LED is flashing. The unit is in standby mode.
)
Initial installation offers the advantage that the time cycles for filter cleaning and change inter-
vals do not start until after this setting has been made.
ª
Section "B.PRO Control control electronics"
– Switch off the unit at the "Unit On/Off" button.
"Unit On/Off" button LED is permanently lit.
Complete initial installation
– Confirm initial filter installation. Press the OK button for 3 seconds.
Initial installation is now complete. The time cycles for filter cleaning/change intervals start now.
L
If the unit is switched on, the optional socket outlet is live at all times. The socket outlet can-
not be switched off separately.
)
Follow the specifications and instructions when connecting electrical appliances.
)
Do not feed the mains connection cable via the induction hob heatable elements.
)
Do not pinch or bend the mains connection cable or route it over sharp edges.
)
The unit lower surface contains a connection for electrical bonding. Connect units which are
operated together via the potential equalisation connection as per the regulations applicable in
the country where they are installed.
)
No external gas-operated units may be operated together with the COOK I-flex.
)
External devices that generate a naked flame during operation must not be operated together
with the COOK I-flex.
9
The voltage, mains frequency and power consumption for external devices comply with the
values specified in "Technical data".