OPERATING INSTRUCTIONS

Assembly prerequisites

Selecting installation
location

Installation dimensions

Installing the unit

36
Unit model, built-in variant – COOK I-flex 1/2/3 built-in
9
Experienced personnel
9
Qualified electrician for installing the unit electrics on site
9
Unit has reached room temperature
9
There are no signs of defects or visible damage to the unit
9
Any existing protective film is completely removed
9
Room air system installed
)
Observe the following points when selecting where to place the unit to ensure that it can ope-
rate to optimum effect:
– Suitable installation location (not next to equipment which develops large amounts of
steam, e.g. not next to a dishwasher)
– Draught-free environment
– Suitable serving line (fire-resistant material, no heat accumulation)
– Installation location suitable for channelling away exhaust air (no back pressure possible).
See Sub-section "Selecting location" for reference details
– Installation location contains maintenance panel, so that any condensation water can be
wiped up.
– Cook shop with output less than 25 kW
Model
Body dimensi-
ons
W x D x H [mm]
2
925 x 678 x 800
3
1255 x 678 x 800 1255 x 678 x 1206
)
If the unit needs to be connected to the power supply with a fixed electrical connection on
site, the customer-supplied installation must be equipped with a disconnection device acting
on all poles which is accessible at all times and can be secured to ensure it is not switched on
accidentally.
Caution!
Damage and personal injury
Tools and auxiliary equipment are required to install the unit or make electric connections to the
unit. This may lead to personal injury and damage to property.
– Always use suitable protective equipment (e.g. protective eyewear, protective gloves).
– Have the assembly and electrical connection carried out by qualified personnel.
– The German Employers' Liability Insurance Association rules and any other applicable natio-
nal provisions for countries of use must be observed in their current version during assembly
and when installing the electrics.
Overall module di-
Ventilation shaft di-
mensions
mensions
W x D x H [mm]
W x D [mm]
925 x 678 x 1206
Connected
load
ª
Chapter
"Technical
280 x 600
data"